Home / Calculators & references
mAh to Wh
Convert milliamp-hours to watt-hours using nominal battery voltage. Compare energy ratings across voltages with the formula and worked battery examples.
Wh = mAh × V / 1000
How to convert mAh to Wh
Divide milliamp-hours by 1,000 to obtain amp-hours, then multiply by nominal voltage. A 10,000 mAh battery at 3.7 V stores approximately 37 Wh; the same charge capacity at 12 V represents 120 Wh.
Conversion examples
| Capacity | Nominal voltage | Energy |
|---|---|---|
| 1000 mAh | 3.7 V | 3.7 Wh |
| 5000 mAh | 3.7 V | 18.5 Wh |
| 10000 mAh | 3.7 V | 37 Wh |
| 10000 mAh | 12 V | 120 Wh |
Which voltage should you enter?
Use the nominal voltage associated with the rated charge capacity, not an unrelated charger or USB output voltage. A power bank rated at 3.7 V may deliver energy through a 5 V output; conversion losses mean delivered energy is lower than its nominal stored energy. Battery voltage changes during discharge, so this is an approximation.
For series packs, use the pack voltage and pack charge capacity rather than multiplying the capacity by the number of series cells. Parallel identical cells increase charge capacity while nominal voltage stays the same.
Related tools
Wh to mAh · Battery runtime · kWh calculator.
Compare charge capacity at different voltages
Two hypothetical batteries both rated at 5,000 mAh do not necessarily store the same energy. At 3.7 V the nominal estimate is 18.5 Wh; at 7.4 V it is 37 Wh. Their voltage ratings are essential to a fair energy comparison. A 10,000 mAh power bank rated at its internal 3.7 V nominal voltage does not imply 10,000 mAh at the USB connector.
The nominal-energy approximation uses charge capacity times nominal voltage. Exact delivered energy depends on the voltage over the discharge interval and losses. To convert in the other direction, use Wh to mAh. For a runtime estimate under stated efficiency assumptions, use the battery runtime calculator.
Battery energy comparison at different nominal voltages
The table uses the nominal-energy approximation Wh = mAh × V / 1,000. Each column is a different hypothetical nominal voltage, not an output-voltage setting.
| Charge capacity | 3.7 V | 5 V | 7.4 V | 12 V | 24 V |
|---|---|---|---|---|---|
| 100 mAh | 0.37 Wh | 0.5 Wh | 0.74 Wh | 1.2 Wh | 2.4 Wh |
| 500 mAh | 1.85 Wh | 2.5 Wh | 3.7 Wh | 6 Wh | 12 Wh |
| 1000 mAh | 3.7 Wh | 5 Wh | 7.4 Wh | 12 Wh | 24 Wh |
| 2000 mAh | 7.4 Wh | 10 Wh | 14.8 Wh | 24 Wh | 48 Wh |
| 3000 mAh | 11.1 Wh | 15 Wh | 22.2 Wh | 36 Wh | 72 Wh |
| 5000 mAh | 18.5 Wh | 25 Wh | 37 Wh | 60 Wh | 120 Wh |
| 7500 mAh | 27.75 Wh | 37.5 Wh | 55.5 Wh | 90 Wh | 180 Wh |
| 10000 mAh | 37 Wh | 50 Wh | 74 Wh | 120 Wh | 240 Wh |
| 15000 mAh | 55.5 Wh | 75 Wh | 111 Wh | 180 Wh | 360 Wh |
| 20000 mAh | 74 Wh | 100 Wh | 148 Wh | 240 Wh | 480 Wh |
| 25000 mAh | 92.5 Wh | 125 Wh | 185 Wh | 300 Wh | 600 Wh |
| 30000 mAh | 111 Wh | 150 Wh | 222 Wh | 360 Wh | 720 Wh |
For example, 20,000 mAh at 3.7 V corresponds to approximately 74 Wh, while 20,000 mAh at 7.4 V corresponds to 148 Wh. A charge-capacity number cannot be compared fairly without the associated voltage.
How to read a battery label
A label might state 5 Ah instead of 5,000 mAh. Those values describe the same nominal charge capacity. The tool uses mAh, so multiply Ah by 1,000 before entering the capacity. If a rating already lists energy in Wh, a second conversion from mAh is unnecessary unless checking the consistency of the label.
The nominal voltage must describe the same rated capacity. A product with an internal battery and a regulated output may have different internal and output voltages. Using the output voltage with an internal charge rating can yield a misleading nominal-energy estimate. Consult the rating conventions in the manufacturer's documentation.
Nominal energy versus delivered energy
Charge capacity describes the amount of electric charge associated with a specified discharge condition. Stored or delivered energy also depends on voltage throughout that discharge interval. The approximation multiplies charge by a representative nominal voltage; it is not the exact integral of changing voltage over charge.
Suppose a hypothetical product has an estimated nominal 37 Wh rating and an independently established 80% delivered-energy fraction for a specified load condition. The estimated delivered energy under those assumptions is 29.6 Wh. That illustration does not imply an actual battery has an 80% conversion efficiency or a particular usable-energy fraction.
What changes when batteries are compared?
A 6,000 mAh rating at 3.7 V corresponds to 22.2 Wh. A 3,000 mAh rating at 7.4 V also corresponds to 22.2 Wh under the nominal approximation. The second number in mAh is smaller, but the nominal energy is the same. That does not establish equal battery performance, runtime, voltage compatibility or physical interchangeability.
Reverse the calculation
For 37 Wh at 3.7 V, dividing energy by voltage gives 10 Ah, then multiplying by 1,000 gives 10,000 mAh. The Wh to mAh calculator performs that reverse calculation. To estimate operating time, use battery runtime with appropriate load and loss assumptions.
Zero charge capacity with positive nominal voltage gives zero nominal energy. Nonpositive voltage does not describe a supported battery nominal rating in this tool. The result is rounded for display and is not a certification of energy available under any real operating condition.
Frequently asked questions
Is 10000 mAh always 37 Wh?
No. That value assumes a nominal battery voltage of 3.7 V.