Home / Calculators & references
Watts to kWh
Convert watts to kilowatt-hours for a single load using operating time. See the energy formula, time conversion examples and a quick reference table.
E = P × t ÷ 1,000
Watts to kilowatt-hours conversion
Watts cannot be converted to kilowatt-hours without a time interval. For constant power, multiply watts by hours and divide by 1,000. For example, 750 W operating for two hours uses 1.5 kWh.
Conversion table
| Power | 30 minutes | 1 hour | 24 hours |
|---|---|---|---|
| 50 W | 0.025 kWh | 0.05 kWh | 1.2 kWh |
| 100 W | 0.05 kWh | 0.1 kWh | 2.4 kWh |
| 500 W | 0.25 kWh | 0.5 kWh | 12 kWh |
| 1000 W | 0.5 kWh | 1 kWh | 24 kWh |
These figures assume uninterrupted operation at the given real power. Convert minutes to hours by dividing by 60. For variable loads, use the time-weighted average power.
Using energy estimates
If you know the price per kWh, multiply the result by that rate to estimate energy charges. The electricity cost calculator handles daily and monthly estimates. Use the kWh calculator when several identical devices operate together.
Convert watts and minutes to kWh
For a single load running for a specified number of minutes, convert the time to hours first: E = W × minutes / 60,000. A 900 W load running for 20 minutes uses 0.3 kWh. For seconds, divide W × seconds by 3,600,000. A 100 W load running for 90 seconds uses 0.0025 kWh.
Reverse the conversion
If you know the energy and the duration, average power in watts equals 1,000 × kWh / hours. For example, 0.75 kWh over 3 hours corresponds to 250 W. The duration must be greater than zero. This is average power over the interval, not necessarily the maximum power the equipment draws.
Constant versus changing power
The conversion table assumes steady power. For a changing load, add the energy for each time interval, or multiply the time-weighted average by the total duration. To estimate multiple identical devices at once, use the kWh calculator. If you already have a measured kWh reading, no watts-to-kWh conversion is needed.
Reference: OpenStax, Electrical Energy and Power.
Convert watts at common operating times
This table uses a single constant-power load. Results are in kWh, not watts or kilowatts. Time is essential because energy accumulates over the interval.
| Power | 15 min | 30 min | 1 hour | 8 hours | 24 hours |
|---|---|---|---|---|---|
| 10 W | 0.0025 | 0.005 | 0.01 | 0.08 | 0.24 |
| 25 W | 0.00625 | 0.0125 | 0.025 | 0.2 | 0.6 |
| 50 W | 0.0125 | 0.025 | 0.05 | 0.4 | 1.2 |
| 75 W | 0.01875 | 0.0375 | 0.075 | 0.6 | 1.8 |
| 100 W | 0.025 | 0.05 | 0.1 | 0.8 | 2.4 |
| 150 W | 0.0375 | 0.075 | 0.15 | 1.2 | 3.6 |
| 200 W | 0.05 | 0.1 | 0.2 | 1.6 | 4.8 |
| 250 W | 0.0625 | 0.125 | 0.25 | 2 | 6 |
| 500 W | 0.125 | 0.25 | 0.5 | 4 | 12 |
| 750 W | 0.1875 | 0.375 | 0.75 | 6 | 18 |
| 1000 W | 0.25 | 0.5 | 1 | 8 | 24 |
| 1500 W | 0.375 | 0.75 | 1.5 | 12 | 36 |
| 2000 W | 0.5 | 1 | 2 | 16 | 48 |
A 100 W load for 24 hours uses 2.4 kWh. A 1,500 W load for 30 minutes uses 0.75 kWh. These are mathematical examples assuming constant real power throughout the stated interval, not typical appliance consumption claims.
Convert minutes and seconds correctly
The calculator takes hours. Divide minutes by 60; divide seconds by 3,600. For example, 45 minutes is 0.75 hours, and 90 seconds is 0.025 hours. An illustrative 800 W load running for 45 minutes uses 0.6 kWh. Entering 45 as hours would produce an answer 60 times too large.
For a short operation, 200 W running for 90 seconds gives 5 Wh, or 0.005 kWh. Small numbers can still be meaningful: the tool displays kWh and the equivalent Wh so the scale is easier to interpret.
What if power varies during the interval?
For a hypothetical single load with 500 W for 20 minutes and 100 W for 40 minutes, the energy estimates are approximately 0.1667 kWh and 0.0667 kWh. Their sum is about 0.2333 kWh. Equivalently, the time-weighted average is approximately 233.3 W over the hour.
If a device has a standby mode, include the time and average power for that mode separately when relevant. The maximum nameplate wattage may not be representative of the full interval. A measured energy value for the operation avoids the need to infer energy from a constant-power approximation.
kWh, Wh, kW and W
One kWh equals 1,000 Wh. One kW equals 1,000 W. The first pair describes energy and the second describes power. The same multiplier does not make energy and power interchangeable. For example, a 1 kW load operated for two hours consumes 2 kWh, whereas a 2 kW load operated for half an hour consumes 1 kWh.
Use the result for a single interval
This converter is intended for a known wattage and a specified duration. For multiple identical appliances, use the kWh calculator with a device count. For a daily schedule and billing-period estimate, use the electricity cost calculator. If you already have measured kWh, no watts-to-kWh conversion is required.
The tool rejects missing and negative inputs, while zero power or zero duration returns zero under the mathematical model. It does not calculate output from a variable power source or a solar installation without appropriate average-power information. Read power versus energy for the conceptual distinction.
Frequently asked questions
How many kWh is 1500 watts for 2 hours?
3 kWh, assuming a constant real power of 1500 W.