Battery Runtime Calculator
Estimate battery runtime in hours from nominal watt-hours, average load, usable energy and conversion efficiency. Compare delivered and stored energy.
Runtime = Wh × usable fraction × efficiency / W
Estimate only. Actual runtime depends on discharge rate, battery age, temperature, BMS cutoff and load variation. Use measured usable energy where available.
Energy budget
LIVE VIEWBars share a common scale within this view.
Estimate battery operating time
Enter nominal battery energy in watt-hours, average load power, the usable fraction of stored energy and conversion efficiency. The tool estimates operating time in hours under a constant-load model. The default percentages are illustrative assumptions, not recommended discharge limits.
Worked example
A 500 Wh battery with 90% usable energy and 85% conversion efficiency delivers an estimated 382.5 Wh to a load. At 60 W, runtime is about 6.375 hours. At 120 W, it is about 3.19 hours under the same assumptions.
| Load | Estimated runtime from 382.5 Wh |
|---|---|
| 30 W | 12.75 h |
| 60 W | 6.375 h |
| 120 W | 3.1875 h |
| 250 W | 1.53 h |
Why actual runtime differs
Battery capacity varies with temperature, age, discharge rate and cutoff voltage. Inverters may draw idle power even when the connected device is off. If efficiency excludes idle consumption, include the relevant idle consumption in an appropriately defined power budget. Some loads have starting surges; this calculator does not determine whether the battery or inverter can supply them.
For a battery labeled in mAh, first use mAh to Wh. Compare the estimate with manufacturer discharge curves and rated operating conditions. Do not use this estimate to plan safety-critical backup power.
Related tools
Wh to mAh · Electricity cost calculator.
Estimate several operating modes separately
If the load changes, calculate total energy used during each interval, or find the time-weighted average load. As an illustrative example, a device drawing 20 W for 45 minutes and 100 W for 15 minutes each hour averages 40 W. With 180 Wh estimated delivered energy, the simplified runtime is 4.5 hours. If conversion losses or load power vary, the result is only an approximation.
Use the correct energy rating
A battery label may state Ah rather than Wh. Multiply Ah by the associated nominal voltage to estimate rated Wh, or use mAh to Wh. If you have already measured energy delivered at the load, do not deduct conversion losses a second time. For planning the opposite question, use the battery capacity calculator. Manufacturer test conditions and discharge curves take precedence over these estimates.
Runtime table for a specified delivered-energy budget
The table compares mathematical durations from three hypothetical delivered-energy quantities. Delivered energy here already includes the assumed losses; do not apply the losses again.
| Average load | 100 Wh delivered | 250 Wh delivered | 500 Wh delivered |
|---|---|---|---|
| 5 W | 20 h | 50 h | 100 h |
| 10 W | 10 h | 25 h | 50 h |
| 15 W | 6.6667 h | 16.667 h | 33.333 h |
| 20 W | 5 h | 12.5 h | 25 h |
| 30 W | 3.3333 h | 8.3333 h | 16.667 h |
| 40 W | 2.5 h | 6.25 h | 12.5 h |
| 50 W | 2 h | 5 h | 10 h |
| 60 W | 1.6667 h | 4.1667 h | 8.3333 h |
| 75 W | 1.3333 h | 3.3333 h | 6.6667 h |
| 100 W | 1 h | 2.5 h | 5 h |
| 150 W | 0.66667 h | 1.6667 h | 3.3333 h |
| 250 W | 0.4 h | 1 h | 2 h |
For example, 250 Wh delivered and 50 W average power correspond to five hours. The same available energy at 100 W corresponds to 2.5 hours. These results describe the constant-average-load model rather than discharge curves for specific battery products.
Identify which battery rating you have
A product may list nominal stored energy, usable energy, capacity in Ah, or measured delivered energy under specific test conditions. Those quantities are not necessarily interchangeable. Nominal charge capacity multiplied by nominal voltage provides an approximate Wh value. Use mAh to Wh for a charge rating expressed in milliamp-hours.
If measured delivered energy is already known at the load, entering it as nominal energy and then reducing it again for the same losses would underestimate the budget. In a simplified estimate, apply each assumed loss once. Use manufacturer test conditions and relevant measured data in preference to arbitrary percentages.
Estimate a repeating workload
Consider a hypothetical repeating one-hour schedule with 15 W for forty minutes, 60 W for fifteen minutes and 5 W for five minutes. Energy used is 10 + 15 + 0.4167 = 25.4167 Wh per hour, so the average load is about 25.42 W. If the independently estimated delivered energy is 200 Wh, the simplified duration is about 7.87 hours.
The schedule assumes the same cycle repeats throughout the estimate. A different workload, cutoff event or change in efficiency can change the actual duration. For variable loads, a measured energy-per-cycle value may be more useful than the maximum wattage.
Interpret the energy-budget chart
The first bar represents nominal energy. The second multiplies nominal energy by the usable fraction. The third applies conversion efficiency to that usable amount. The bars therefore depict the successive mathematical assumptions; they do not indicate measured battery state of charge.
If usable energy or efficiency is zero, estimated delivered energy and runtime are zero for positive load. If load power is zero, division does not produce a meaningful finite operating-time estimate in this model. The tool rejects that denominator rather than promising unlimited runtime.
Factors that require independent information
Actual delivered energy can depend on discharge rate, temperature, age, battery management cutoffs and product specifications. The simplified model does not evaluate peak current, compatibility, charging requirements or whether a particular system can safely operate a device. For a target duration rather than a known battery rating, use battery capacity calculator. For the basic distinction between rates and stored quantities, see power versus energy.
Frequently asked questions
Why is actual battery life shorter than the calculation?
Usable capacity, temperature, load variation, inverter losses and battery aging may reduce runtime.