Home / Calculators & references

Wh to mAh

Convert watt-hours to milliamp-hours using the nominal battery voltage. Compare equivalent charge capacities with formulas and examples at different voltages.

CALCULATOR WORKSPACE Live calculation
Calculated result—

mAh = 1000 × Wh / V

Convert battery energy to charge capacity

Multiply watt-hours by 1,000 and divide by nominal battery voltage. A 37 Wh battery at 3.7 V has an equivalent charge capacity of 10,000 mAh. At 12 V the same nominal energy corresponds to approximately 3,083 mAh.

Energy Voltage Equivalent capacity
10 Wh 5 V 2000 mAh
37 Wh 3.7 V 10000 mAh
60 Wh 12 V 5000 mAh
100 Wh 24 V 4167 mAh

Comparing batteries

Watt-hours are useful for comparing nominal energy across different voltages. Milliamp-hours alone are not sufficient. For example, a 5,000 mAh battery at 12 V has more nominal energy than a 10,000 mAh battery at 3.7 V. Use the manufacturer's nominal pack voltage; do not assume the output connector voltage equals the internal battery voltage.

The calculation does not account for conversion losses, discharge rate, battery age or cutoff voltage. It does not establish safe charging settings.

Related tools

mAh to Wh · Battery runtime.

Convert Wh to Ah before converting to mAh

For an illustrative 48 Wh pack at a nominal voltage of 12 V, divide 48 by 12 to obtain 4 Ah, then multiply by 1,000 to obtain 4,000 mAh. At 24 V, the same nominal energy corresponds to 2,000 mAh. A lower numerical charge capacity does not necessarily mean less stored energy when the pack voltage differs.

Use the voltage corresponding to the published energy rating, rather than the charger voltage or a converted output voltage. The result represents an equivalent nominal charge capacity, not a guaranteed delivered charge. Battery voltage changes over discharge, so manufacturer-rated Wh and measured energy are preferable when available. See mAh to Wh for the inverse and battery capacity calculator for a nominal energy budget.

Convert energy ratings at common nominal voltages

The following results are equivalent nominal milliamp-hour values. They assume the energy rating and voltage describe the same hypothetical battery.

Nominal energy 3.7 V 5 V 7.4 V 12 V 24 V
1 Wh 270.27 200 135.14 83.333 41.667
5 Wh 1351.4 1000 675.68 416.67 208.33
10 Wh 2702.7 2000 1351.4 833.33 416.67
20 Wh 5405.4 4000 2702.7 1666.7 833.33
30 Wh 8108.1 6000 4054.1 2500 1250
37 Wh 10000 7400 5000 3083.3 1541.7
50 Wh 13514 10000 6756.8 4166.7 2083.3
60 Wh 16216 12000 8108.1 5000 2500
74 Wh 20000 14800 10000 6166.7 3083.3
100 Wh 27027 20000 13514 8333.3 4166.7
200 Wh 54054 40000 27027 16667 8333.3
500 Wh 135140 100000 67568 41667 20833

At fixed energy, a higher nominal voltage corresponds to a lower equivalent charge capacity. For example, 100 Wh at 5 V corresponds to 20,000 mAh, while 100 Wh at 20 V corresponds to 5,000 mAh. The examples do not describe interchangeable products.

Determine the correct voltage before converting

The conversion is based on nominal stored energy and the voltage associated with that rating. If a battery system provides a regulated output, the output voltage can differ from the internal pack's nominal voltage. A charge-capacity figure computed from a different voltage does not necessarily match the manufacturer's internal rating.

A manufacturer may state energy in Wh directly, which is often useful for comparing nominal energy across voltages. The equivalent charge calculation does not predict output current limits, maximum load, charging behavior or compatibility. When interpreting a product label, use its stated rating conditions.

Convert from Wh to Ah first

Divide Wh by nominal volts to obtain equivalent amp-hours, then multiply by 1,000 for milliamp-hours. For an illustrative 24 Wh rating at 12 V, the calculation gives 2 Ah or 2,000 mAh. If the original energy is expressed in kWh, multiply by 1,000 to obtain Wh before entering it. A 0.1 kWh rating equals 100 Wh.

Do not confuse milliamp-hours with milliamperes. Milliamp-hours measure charge, whereas milliamperes measure current. A 2,000 mAh rating alone does not identify either current at a particular instant or a guaranteed two-hour runtime at a given load.

Compare equivalent charge with delivered energy

A nominal energy estimate and actual delivered energy can differ. If an independently measured output delivers 30 Wh at a nominal regulated 5 V, the simplified equivalent output charge is 6,000 mAh. That is a different quantity from an internal cell rating at 3.7 V. The calculation does not reconstruct internal battery capacity without the relevant conversion and discharge information.

Verify the result and choose the next tool

Multiply the computed milliamp-hours by the same nominal voltage and divide by 1,000 to recover the original Wh. The mAh to Wh calculator supports this reverse check. For actual energy-budget estimates, use battery capacity or battery runtime.

The denominator must be positive because zero voltage cannot identify a finite equivalent charge capacity. Negative magnitudes are outside the model. Zero energy at positive voltage yields zero. See calculation methodology for the limitations of nominal-energy calculations.

Frequently asked questions

Can I convert Wh to mAh without voltage?

No. The nominal voltage is required.