Home / Calculators & references

Voltage Divider Calculator

Calculate the output of a two-resistor voltage divider with or without a resistive load. Enter input voltage and resistance values to see the voltage ratio.

CALCULATOR WORKSPACE Live calculation
VinR1R2Vout—
Calculated result—

Voltage distribution

LIVE VIEW
Input—
Upper resistor drop—
Output—

Bars share a common scale within this view.

Voltage divider equation

For two series resistors with no external load, output voltage across the lower resistor is Vout = Vin × R2 / (R1 + R2). This calculator also supports a resistive load connected across R2. Enter zero in the load field to represent a disconnected load, not a short circuit.

Loaded voltage divider

When a load RL is present, replace R2 by the equivalent resistance R2 × RL / (R2 + RL). The output voltage falls because that equivalent resistance is lower than R2 alone. The upper resistor current is Vin divided by the sum of R1 and the equivalent lower resistance.

Worked examples

A 12 V input with two 10 kΩ resistors gives 6 V unloaded. Connecting a 10 kΩ load makes the lower equivalent resistance 5 kΩ and reduces the output to 4 V. A 100 kΩ load gives about 5.714 V.

R1 R2 Input Unloaded output
1 kΩ 1 kΩ 5 V 2.5 V
2 kΩ 1 kΩ 12 V 4 V
10 kΩ 30 kΩ 12 V 9 V

When not to use a divider

A resistive divider is not a regulated power supply. Its voltage depends on the load, and the resistors dissipate power. The tool assumes ideal linear resistors and a steady DC source; it does not assess component ratings, transient response or electrical safety. For a sensitive measurement, include input impedance in the load field.

Related tools

Parallel resistor calculator · Ohm’s law · LED resistor calculator.

Understanding the load diagram

The added RL branch is connected across R2. The lower branch therefore consists of two parallel resistances, not three resistors in series. With no external load, the diagram shows only R1 and R2. For a finite load, use the same equivalent-resistance calculation described in our parallel resistor calculator. The voltage bars compare the input, the upper resistor voltage drop and the output on one scale; the upper drop plus output equals the input in the ideal model.

Load sensitivity example

For an ideal 10 V input with R1 = 20 kΩ and R2 = 20 kΩ, the unloaded output is 5 V. With a 20 kΩ load, the lower equivalent resistance is 10 kΩ and the output is approximately 3.33 V. A much larger load resistance changes the result less. This illustrates loading error rather than providing a component recommendation.

Reference: OpenStax, resistors in series and parallel.

Compare the output as load resistance changes

The following numerical examples use a hypothetical ideal 12 V source and two 10 kΩ resistors. The unloaded case has no external resistance connected across the lower branch. The finite load cases use an additional ideal resistor in parallel with R2.

External load Equivalent lower resistance Estimated output
Disconnected 10000 Ω 6 V
1000 Ω 909.09 Ω 1 V
2000 Ω 1666.7 Ω 1.7143 V
5000 Ω 3333.3 Ω 3 V
10000 Ω 5000 Ω 4 V
20000 Ω 6666.7 Ω 4.8 V
47000 Ω 8245.6 Ω 5.4231 V
100000 Ω 9090.9 Ω 5.7143 V
220000 Ω 9565.2 Ω 5.8667 V
1000000 Ω 9901 Ω 5.9701 V

As the finite load resistance increases, the equivalent lower resistance approaches R2 and the output approaches the unloaded value. A smaller load resistance produces a larger difference from the unloaded estimate. These are ideal mathematical examples, not recommended component values or connection instructions.

Why the lower branch changes

For the unloaded model, only R1 and R2 determine the output ratio. When a finite external resistance is in parallel with R2, both lower-branch conductances add. The equivalent lower resistance is therefore less than R2 alone. The loaded divider calculation replaces R2 with that equivalent resistance before applying the series ratio.

For a hypothetical 6 V input with R1 and R2 each 2 kΩ, the unloaded output is 3 V. If an additional 2 kΩ resistor is mathematically placed in parallel with R2, the lower equivalent becomes 1 kΩ. The ideal output is then 6 × 1 / (2 + 1) = 2 V, using the same kΩ scale throughout.

Interpret the load field and diagram

In this interface, zero in the load field is a special representation of no external load. It does not represent a physical zero-ohm short circuit. A positive finite load value represents the ideal resistive branch shown in the diagram. Negative and missing resistance inputs are invalid.

The graph compares the input, the voltage difference across the upper resistor and the output voltage under the stated model. The two voltage differences add to the input. The diagram and chart respond to the model's inputs; they are not measurements or validation of an actual circuit.

Consider measurement input impedance

A measuring instrument or connected input may have finite impedance rather than infinite resistance. If its relevant behavior can be represented by a known resistive load, the loaded model illustrates how the ideal output ratio changes. Real instruments may also have capacitance, frequency-dependent impedance, leakage or other characteristics. The model does not account for those effects.

Scope of the model

A resistor divider is not a regulated supply. Its output changes with load and component values, and component dissipation requires separate consideration. The tool assumes ideal linear resistances and steady DC. It does not assess device compatibility, dynamic response, voltage ratings or installation safety.

See parallel resistor calculator for the lower equivalent resistance and Ohm’s law for the ideal voltage-current-resistance relationship. For formal relationships see electrical formulas.

Frequently asked questions

Why does the output voltage fall when a load is connected?

The load is in parallel with the lower resistor and reduces the equivalent resistance.